Removal Procedure
Caution: Refer to Battery Disconnect Caution in the Preface section.
- Remove the upper fan shroud. Refer to
Engine Coolant Fan Upper Shroud Replacement
.
- Remove the drive belt. Refer to
Drive Belt Replacement
.
- Disconnect the auxiliary generator electrical connector.
- Remove the positive cable from the auxiliary generator, perform the following:
4.1. | Slide the boot down to access the terminal stud. |
4.2. | Remove the positive cable nut. |
4.3. | Remove the positive cable. |
- Remove the auxiliary generator bolts (3).
- Remove the auxiliary generator (4).
Installation Procedure
Notice: Refer to Fastener Notice in the Preface section.
- Position the auxiliary generator (4).
- Install the auxiliary generator bolts (3).
Tighten
Tighten the generator bolts to 50 N·m (37 lb ft).
- Install the positive cable to the auxiliary generator, perform the following:
3.1. | Position the positive cable. |
3.2. | Install the positive cable nut. |
Tighten
Tighten the nut to 10 N·m (89 lb in).
3.3. | Slide the boot to cover the terminal stud. |
- Connect the generator electrical connector.
- Install the drive belt. Refer to
Drive Belt Replacement
.
- Install the upper shroud. Refer to
Engine Coolant Fan Upper Shroud Replacement
.