Test Description

The numbers below refer to the step numbers on the diagnostic table.

  1. The specified values are from the A/C System Performance Test.

  2. The voltage will vary between 0-12 volts during normal operation. The HVAC control assembly connector must be connected during this step.

Step

Action

Value(s)

Yes

No

Schematic Reference: HVAC Schematics

Connector End View Reference: HVAC Connector End Views

DEFINITION: Temperature cannot be adjusted, or the cooling is insufficient during A/C operation.

1

Did you review the HVAC operation and perform the necessary inspections?

--

Go to Step 2

Go to Symptoms - HVAC Systems - Manual

2

  1. Turn ON the ignition, with the engine OFF.
  2. Place the mode switch in any position, except OFF.
  3. Place the blower motor switch in each speed position.

Does the blower motor operate in any of the speed positions?

--

Go to Step 3

Go to Blower Motor Inoperative

3

Does the blower motor operate correctly for each speed position?

--

Go to Step 4

Go to Blower Motor Malfunction

4

  1. Ensure the blower motor switch is ON.
  2. Select an air outlet mode.

Does air flow out of the selected HVAC outlet ducts?

--

Go to Step 5

Go to Air Delivery Improper

5

When A/C is ON, does the customer concern occur?

--

Go to Step 6

Go to Step 8

6

  1. Start the engine.
  2. Place the blower motor switch in the maximum speed position.
  3. Place the mode switch in the BI-LEVEL position.
  4. Place the air temperature switch in the coldest position.

Does the A/C compressor operate?

--

Go to Step 7

Go to HVAC Compressor Clutch Does Not Engage

7

Perform the refrigerant system performance test. Refer to Air Conditioning (A/C) System Performance Test .

Did you find and correct the condition?

--

Go to Step 18

Go to Step  8

8

  1. Observe the drive shaft of the air temperature actuator.
  2. Place the air temperature switch from the coldest position to the warmest position.

Does the air temperature actuator drive shaft rotate at all?

--

Go to Step 9

Go to Step 10

9

Inspect the air temperature door and the air temperature actuator for the following conditions:

    • Misaligned air temperature actuator-- Refer to Temperature Valve Actuator Replacement .
    • Broken or binding linkages or air temperature door
    • Obstruction that prevents the air temperature door from operating within its full range of motion
    • Missing seals to the air temperature door
    • Misaligned seals to the air temperature door

Did you find and correct the condition?

--

Go to Step 18

Go to Testing for Intermittent Conditions and Poor Connections

10

Test the ignition 3 voltage circuit of the air temperature actuator for an open, high resistance or short to ground. Refer to Circuit Testing and Wiring Repairs .

Did you find and correct the condition?

--

Go to Step 18

Go to Step 11

11

Test the ground circuit of the air temperature actuator for an open. Refer to Circuit Testing and Wiring Repairs .

Did you find and correct the condition?

--

Go to Step 18

Go to Step 12

12

Test the air temperature door control circuit of the air temperature actuator for an open, high resistance, short to ground, or short to voltage. Refer to Circuit Testing and Wiring Repairs .

Did you find and correct the condition?

--

Go to Step 18

Go to Step 13

13

Important: Ensure that the HVAC control assembly connector is connected during this step in order to avoid misdiagnosis.

  1. Measure the voltage from the air temperature door control circuit of the air temperature actuator to a good ground.
  2. Place the air temperature switch from coldest position to the warmest position.

Does the voltage measure within the specified values with a smooth transition between COLD and HOT?

0-12 V

Go to Step 15

Go to Step 14

14

Inspect for poor connections at the harness connector of the air temperature actuator. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs .

Did you find and correct the condition?

--

Go to Step 18

Go to Step 16

15

Inspect for poor connections at the harness connector of the HVAC control assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs .

Did you find and correct the condition?

--

Go to Step 18

Go to Step 17

16

Replace the air temperature actuator. Refer to Temperature Valve Actuator Replacement .

Did you complete the replacement?

--

Go to Step 18

--

17

Replace the HVAC control assembly. Refer to Heater and Air Conditioning Control Replacement .

Did you complete the replacement?

--

Go to Step 18

--

18

Operate the system in order to verify the repair.

Did you correct the condition?

--

System OK

Go to Step 2