Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Starting and Charging Schematics | |||
1 | Did you preform the Diagnostic System Check - Vehicle? | Go to Step 2 | |
2 | Turn the ignition switch to the START position. Does the engine crank? | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 3 |
3 | Turn the ignition switch to the START position. Does the starter motor relay click? | Go to Step 10 | Go to Step 4 |
4 |
Does the test light illuminate? | Go to Step 7 | Go to Step 5 |
5 | Inspect for poor connections at the PCM connector, underhood fuse block or ignition switch harness connector. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 26 | Go to Step 6 |
6 | Test the supply voltage circuit of the crank voltage circuit and Crank fuse for an open or high resistance. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 26 | Go to Step 24 |
7 |
Does the test lamp illuminate? | Go to Step 17 | Go to Step 8 |
8 |
Does the test light illuminate? | Go to Step 9 | Go to Step 15 |
9 |
Does the test light illuminate? | Go to Step 16 | Go to Step 13 |
10 |
Does the test lamp illuminate? | Go to Step 11 | Go to Step 21 |
11 | Connect a 30-amp fused jumper between the battery positive voltage circuit of the starter motor relay switch circuit and the supply voltage circuit of the starter solenoid. Does the engine crank? | Go to Step 16 | Go to Step 12 |
12 | Does the fuse in the jumper open? | Go to Step 22 | Go to Step 15 |
13 | Test the control circuit of the starter motor relay for an open or high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 26 | Go to Step 23 |
14 | Test the supply voltage circuit of the starter motor relay coil circuit for an open or high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 26 | Go to Step 19 |
15 | Test the supply voltage circuit of the starter solenoid for an open or high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 26 | Go to Step 20 |
16 | Inspect for poor connections at the starter motor relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 26 | Go to Step 23 |
17 | Inspect for poor connections at the harness connector of the PCM. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 26 | Go to Step 18 |
18 | Replace the PCM. Refer to Control Module References for replacement, setup and programming. Did you complete the replacement? | Go to Step 26 | -- |
19 | Inspect for poor connections at the ignition switch harness connector. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 26 | Go to Step 24 |
20 | Inspect for poor connections at the starter solenoid. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 26 | Go to Step 25 |
21 | Repair the open or high resistance in the battery positive voltage circuit of the Starter Motor relay switch circuit. Refer to Wiring Repairs . Did you complete the repair? | Go to Step 26 | -- |
22 | Repair the short to ground in the supply voltage circuit of the starter solenoid. Refer to Wiring Repairs . Did you complete the repair? | Go to Step 26 | -- |
23 | Replace the Starter Relay. Refer to Relay Replacement . Did you complete the replacement? | Go to Step 26 | -- |
24 | Replace the ignition switch. Refer to Ignition and Start Switch Replacement . Did you complete the replacement? | Go to Step 26 | -- |
25 | Replace the starter. Refer to Starter Motor Replacement . Did you complete the replacement? | Go to Step 26 | -- |
26 | Operate the system for which the symptom occurred. Did you correct the condition? | System OK | Go to Step 1 |
Step | Action | Yes | No | ||||
---|---|---|---|---|---|---|---|
Schematic Reference: Starting and Charging Schematics | |||||||
1 | Did you preform the Diagnostic System Check - Vehicle? | Go to Step 2 | |||||
2 | Turn the ignition switch to the START position. Does the engine crank? | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 3 | ||||
3 | Turn the ignition switch to the START position. Does the starter motor relay click? | Go to Step 14 | Go to Step 4 | ||||
4 | Is the vehicle equipped with a manual transmission? | Go to Step 5 | Go to Step 7 | ||||
5 |
Does the scan tool display Released/Applied? | Go to Step 7 | Go to Step 6 | ||||
6 |
Does the test lamp illuminate? | Go to Step 10 | Go to Step 11 | ||||
7 |
Does the test light illuminate? | Go to Step 10 | Go to Step 8 | ||||
8 | Inspect for poor connections at the PCM connector, underhood fuse block or ignition switch harness connector. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 32 | Go to Step 9 | ||||
9 | Test the supply voltage circuit of the crank voltage circuit and Crank fuse for an open or high resistance. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 32 | Go to Step 30 | ||||
10 |
Does the test lamp illuminate? | Go to Step 22 | Go to Step 11 | ||||
11 |
Does the test light illuminate? | Go to Step 12 | Go to Step 13 | ||||
12 |
Does the test light illuminate? | Go to Step 20 | Go to Step 17 | ||||
13 |
Does the test lamp illuminate? | Go to Step 21 | Go to Step 18 | ||||
14 |
Does the test lamp illuminate? | Go to Step 15 | Go to Step 26 | ||||
15 | Connect a 30-amp fused jumper between the battery positive voltage circuit of the starter motor relay switch circuit and the supply voltage circuit of the starter solenoid. Does the engine crank? | Go to Step 20 | Go to Step 16 | ||||
16 | Does the fuse in the jumper open? | Go to Step 27 | Go to Step 19 | ||||
17 | Test the control circuit of the starter motor relay for an open or high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 32 | Go to Step 28 | ||||
18 | Test the supply voltage circuit of the starter motor relay coil circuit for an open or high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 32 | Go to Step 24 | ||||
19 | Test the supply voltage circuit of the starter solenoid for an open or high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 32 | Go to Step 25 | ||||
20 | Inspect for poor connections at the starter motor relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 32 | Go to Step 28 | ||||
21 | Inspect for the following:
Did you find and correct the condition? | Go to Step 32 | Go to Step 29 | ||||
22 | Inspect for poor connections at the harness connector of the PCM. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 32 | Go to Step 23 | ||||
23 | Replace the PCM. Refer to Control Module References for replacement, setup and programming. Did you complete the replacement? | Go to Step 32 | -- | ||||
24 | Inspect for poor connections at the ignition switch harness connector. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 32 | Go to Step 30 | ||||
25 | Inspect for poor connections at the starter solenoid. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 32 | Go to Step 31 | ||||
26 | Repair the open or high resistance in the battery positive voltage circuit of the starter motor relay switch circuit. Refer to Wiring Repairs . Did you complete the repair? | Go to Step 32 | -- | ||||
27 | Repair the short to ground in the supply voltage circuit of the starter solenoid. Refer to Wiring Repairs . Did you complete the repair? | Go to Step 32 | -- | ||||
28 | Replace the starter relay. Refer to Relay Replacement . Did you complete the replacement? | Go to Step 32 | -- | ||||
29 |
Did you complete the replacement? | Go to Step 32 | -- | ||||
30 | Replace the ignition switch. Refer to Ignition and Start Switch Replacement . Did you complete the replacement? | Go to Step 32 | -- | ||||
31 | Replace the starter. Refer to Starter Motor Replacement . Did you complete the replacement? | Go to Step 32 | -- | ||||
32 | Operate the system for which the symptom occurred. Did you correct the condition? | System OK | Go to Step 2 |