Removal Procedure
- Raise and support the window glass.
- Remove the trim panel. Refer to
Front Side Door Trim Panel Replacement.
- Remove the water deflector. Refer to
Front Side Door Water Deflector Replacement.
- Remove the 2 bolts that hold the window to the regulator.
- Remove the bolts from the window regulator.
- Remove the window regulator assembly from the door by folding both sides together.
Installation Procedure
- Position the regulator to the inside door structure. A slight twisting motion of the regulator is needed.
- Ensure the regulator is positioned firmly in the door.
Notice: Refer to Fastener Notice in the Preface section.
Important: Place Permatex Threadlocker, Part Number 24200, GM P/N 12345382, onto the regulator bolt threads prior to tightening.
- Install the bolts to the window regulator.
Tighten
Tighten the bolts to 9 N·m (80 lb in).
- Align the window glass to the regulator.
- Install the bolts that hold the window to the regulator.
Tighten
Tighten the bolts to 9 N·m (80 lb in).
- Install the water deflector. Refer to
Front Side Door Water Deflector Replacement.
- Install the trim panel. Refer to
Front Side Door Trim Panel Replacement.
- Lower the window and inspect the operation.