Removal Procedure
Important: Clean the fuel and evaporative emission (EVAP) connections and surrounding areas prior to disconnecting the lines in order to avoid possible system contamination.
- Relieve the fuel system pressure. Refer to
Fuel Pressure Relief
.
- Drain the fuel tank. Refer to
Fuel Tank Draining
.
- Remove the fuel tank fill pipe. Refer to
Filler Tube Replacement
.
- Remove the EVAP canister vent solenoid. Refer to
Evaporative Emission Canister Vent Solenoid Valve Replacement
.
- Remove the fuel tank shield bolts, if equipped.
- Remove the fuel tank shield, if equipped.
- Disconnect the fuel feed and EVAP lines. Refer to
Plastic Collar Quick Connect Fitting Service
.
- Cap the fuel and EVAP lines in order to prevent possible system contamination.
- Place a suitable adjustable jack under the fuel tank.
- Remove the fuel tank strap bolts.
- Remove the fuel tank straps.
- Lower the fuel tank half way.
When lowering the tank, ensure that the fill neck on the tank does not get hung up on the harness.
- Disconnect the electrical harness clip at the frame crossmember.
- Lower the fuel tank until the electrical connections are accessible.
- Disconnect the fuel pressure sensor electrical connector (1).
- Disconnect the fuel sending unit electrical connector (2), perform the following:
16.1. | Disengage the gray retainer. |
16.2. | Push down the black clip. |
16.3. | Disconnect the connector. |
- Completely lower the fuel tank.
- With the aid of an assistant, place the fuel tank in a suitable work area.
- If necessary, disconnect and remove the fuel feed line (1) from the sending unit and retaining clips.
- If necessary, disconnect and remove the EVAP purge line (2) from the retaining clips.
- If necessary, disconnect and remove the EVAP fuel level vent valve (FLVV) line from the FLVV, sending unit, and retaining clips.
- If necessary, remove the sending unit. Refer to
Fuel Sender Assembly Replacement
.
Installation Procedure
- If necessary, install the sending unit. Refer to
Fuel Sender Assembly Replacement
.
- If necessary, install and connect the EVAP FLVV line to the FLVV, sending unit, and retaining clips.
- If necessary, install and connect the EVAP purge line (2) to the retaining clips.
- If necessary, install and connect the fuel feed line (1) to the sending unit and retaining clips.
- With the aid of an assistant, place the fuel tank onto the adjustable jack.
- Raise the fuel tank until the electrical connections can be made.
- Connect the fuel sending unit (2) and pressure sensor (1) electrical connectors.
- Completely raise the fuel tank.
When raising the tank, ensure that the fill neck on the tank goes over the harness.
Notice: Refer to Fastener Notice in the Preface section.
- Install the fuel tank straps.
- Install the fuel tank strap bolts.
Tighten
Tighten the bolts to 40 N·m (30 lb ft).
- Remove the adjustable jack from under the fuel tank.
- Remove the caps from the fuel and EVAP lines.
- Connect the fuel feed and EVAP lines. Refer to
Plastic Collar Quick Connect Fitting Service
.
- If necessary, install the fuel tank shield.
- If necessary, install the fuel tank shield bolts.
Tighten
Tighten the bolts to 18 N·m (13 lb ft).
- Install the EVAP canister vent solenoid. Refer to
Evaporative Emission Canister Vent Solenoid Valve Replacement
.
- Install the fuel tank fill pipe. Refer to
Filler Tube Replacement
.
- Refill the fuel tank.
- Install the fuel cap.
- Connect the negative battery cable. Refer to
Battery Negative Cable Disconnection and Connection
.
- Perform the following procedure in order to inspect for leaks:
21.1. | Turn the ignition ON, with the engine OFF, for 2 seconds. |
21.2. | Turn the ignition OFF for 10 seconds. |
21.3. | Turn the ignition ON, with the engine OFF. |
21.4. | Inspect for fuel leaks. |