Removal Procedure
- Remove the air cleaner outlet resonator. Refer to
Air Cleaner Outlet Resonator Replacement
.
- Disconnect the idle air control (IAC) valve electrical connector (2).
- Remove the IAC valve screws.
- Remove the IAC valve and O-ring seal.
Cleaning and Inspection Procedure
Clean the IAC valve O-ring sealing surface, pintle valve seat, and air passage.
• | Remove any excess carbon deposits with a small amount of carburetor cleaner on a parts cleaning brush. Follow any instructions on the cleaner container regarding cleaner usage. |
• | Do not use a cleaner containing an extremely powerful solvent such as methyl ethyl ketone. |
• | Shiny spots on the pintle and seat do not represent a bent or misaligned pintle shaft. |
• | If heavy deposits are present in the air passage, remove the throttle body for a complete cleaning. Refer to
Throttle Body Cleaning
. |
Installation Procedure
- If installing a NEW IAC valve, measure the distance between the IAC valve pintle
and the mounting flange. If the distance is more than 28 mm (1.10 in), use finger pressure, and gently push in the pintle.
- Install a NEW IAC valve O-ring seal.
- Lubricate the IAC valve O-ring seal with clean engine oil.
- Install the IAC valve and O-ring seal.
- If installing the old IAC valve, clean the old thread locking material from the
screws.
- If installing the old IAC valve coat the screw threads with threadlock GM P/N 12345382 (Canadian P/N 10953489), or equivalent.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the IAC valve screws.
Tighten
Tighten the screws to 3 N·m (27 lb in).
- Connect the IAC valve electrical connector (2).
- Install the air cleaner outlet resonator. Refer to
Air Cleaner Outlet Resonator Replacement
.
- Perform the IAC reset procedure:
10.1. | Turn the ignition to the ON position, wait for 5 seconds. |
10.2. | Turn the ignition to the OFF position, wait for 10 seconds. |
10.3. | Start the engine and check for proper idle speed. |