Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
---|---|---|---|
Ignition ON/Engine Running | |||
Desired Accessory Power | HCM Data Display | Volts | 9-14 V |
Aux. Power Outlets | HCM Data Display | Normal/Continuous | Normal/Continuous |
Aux. Power Outlets Target Idle Speed | HCM Data Display | RPM | 500-1750 |
Aux. Coolant Pump Relay | HCM Data Display | On/Off | On |
Aux. Trans Pump Relay | HCM Data Display | On/Off | On |
Power Maintain Relay | HCM Data Display | On/Off | ON |
Aux. Power Outlets Switch | HCM Data Display | On/Off | On |
Acc. Power Module DC/DC Direction | HCM Data Display | 14-42 V 42-14 V | 14-42 V |
Ignition 1 | HCM Data Display | On/Off | On |
Hood Switch Status | HCM Data Display | Open/Closed | Closed |
Acc. Power Load | HCM Data Display | On/Off | On |
Battery Pack Status Discharge | HCM Data Display | On/Off | On |
Battery Pack IEO Discharge Time | HCM Data Display | On/Off | On |
Battery Pack State of Charge Status | HCM Data Display | On/Off | On |
Battery Pack Voltage Status | HCM Data Display | On/Off | On |
Accelerator Pedal Position Status | HCM Data Display | On/Off | On |
ATC Status | HCM Data Display | On/Off | On |
Brake Switch Status | HCM Data Display | On/Off | On |
ECT Status | HCM Data Display | On/Off | On |
Engine Run Time Status | HCM Data Display | On/Off | On |
Engine Speed Status | HCM Data Display | On/Off | On |
Aux. Power Outlet Load Status | HCM Data Display | On/Off | On |
Aux. Power Outlets Status | HCM Data Display | On/Off | On |
Hood Switch Status | HCM Data Display | On/Off | On |
HVAC Status | HCM Data Display | On/Off | On |
Min. Gear State Status | HCM Data Display | On/Off | On |
Min. IEO Status | HCM Data Display | On/Off | On |
PCM Status | HCM Data Display | On/Off | On |
TR Switch Status | HCM Data Display | On/Off | On |
System Operation Status | HCM Data Display | On/Off | On |
TFT Status | HCM Data Display | On/Off | On |
Door Status | HCM Data Display | Open/Closed | Closed |
Vehicle Acceleration (Inertia Status) | HCM Data Display | Yes/No | No |
Vehicle Speed Status | HCM Data Display | Yes/No | Yes |
Ignition 1 Status | HCM Data Display | On/Off | On |
Tow/Haul Mode | HCM Data Display | Active/Inactive | Active |
Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
---|---|---|---|
Ignition ON/Engine Running | |||
Battery Pack Capacity | ESCM Data Display | Ahrs (Amp Hours) | 55 Ahrs |
Battery Pack Min. State of Charge | ESCM Data Display | % | 45% |
Battery Pack State of Charge | ESCM Data Display | % | 55% |
Battery Pack Fan Speed | ESCM Data Display | % | 50% |
Battery Pack Volts | ESCM Data Display | Volts | 36 V |
Battery Pack Current | ESCM Data Display | Amps | Varying |
Battery Pack Ahrs. Discharged | ESCM Data Display | Ahrs. | 360 Ahrs |
Battery Pack Ahrs. Charge | ESCM Data Display | Ahrs. | 377 Ahrs |
Battery Pack Disconnect Status | ESCM Data Display | Open/Closed | Closed |
Battery Pack Service Charge | ESCM Data Display | Complete/Incomplete | Complete |
Battery 1 Volts | ESCM Data Display | Volts | 12.5 V |
Battery 2 Volts | ESCM Data Display | Volts | 12.5 V |
Battery 3 Volts | ESCM Data Display | Volts | 12.5 V |
Battery 1 Temp. | ESCM Data Display | °F | 77 |
Battery 2 Temp. | ESCM Data Display | °F | 77 |
Battery 3 Temp. | ESCM Data Display | °F | 77 |
Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
---|---|---|---|
Ignition ON/Engine Running | |||
Auxiliary Power Outlet (APO) Output Voltage Phase A | SGCM Data Display | Volts | 120 V |
APO Mode | SGCM Data Display | Normal/Continuous | Normal |
Accessory Power Module (APM) Output Voltage | SGCM Data Display | Volts | 13.7 V |
APM Power | SGCM Data Display | kW | -2.0 to +2.5 kW |
SGCM Temperature | SGCM Data Display | ° | -40 to +140°C |
SGCM Fan Speed | SGCM Data Display | % | Varying |
SGCM Pump Status | SGCM Data Display | On/Off | Off |
SGCM Speed Signal | SGCM Data Display | On/Off | On |
SGCM Bus Voltage | SGCM Data Display | Volts | 42 V |
Delivered Starter/Generator Torque | SGCM Data Display | ft-lbs. | Varying - during key crank |
Table 1: | Generator Battery Control Module (GBCM) |
Table 2: | Instrument Panel Cluster (IPC) |
Table 3: | Powertrain Control Module (PCM) |
Table 4: | Theft Deterrent Module (TDM) |
Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
---|---|---|---|
Engine Running | |||
Battery Voltage Signal | Body / GBCM | Volts | 9-14v |
GEN L--Terminal Signal Command | Body / GBCM | Percent | 10-90% |
GM Part Number | VCS / Module ID Information | Number | 12345678 |
Regulated Voltage Control Current Sensor | Body / GBCM | amps | 10-90A |
Running State of Charge | Body / GBCM | Percent | 10-90% |
Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
---|---|---|---|
Ignition ON / Engine OFF | |||
Battery | Input / Output | On / Off | On |
Battery Voltage | Data 1 | Volts | 9-14v |
Ignition 1 | Data 1 | Volts | 9-14v |
Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
---|---|---|---|
Ignition ON / Engine OFF | |||
Crank Request Signal | Engine Data 1 | Yes, No | No |
GEN F--Terminal Signal | Engine Data 2 | Percent | 10-90% |
GEN L--Terminal Signal Command | Engine Data 2 | On / Off | On |
Ignition 1 Signal | Engine Data 1, 2 | Volts | 9-14v |
PNP Switch | Engine Data 1 | Park/Neutral / In Gear | Park/Neutral |
TR Sw. | Engine Data 1 | Park / Reverse / Neutral / Drive 4, 3, 2, 1 / Invalid | Park |
VTD Fuel Disable | Engine Data 1 | Active / Inactive | Inactive |
Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
---|---|---|---|
Ignition ON / Engine OFF | |||
Battery Voltage | Data | Volts | 9-14v |
Ignition Voltage | Data | Volts | 9-14v |
Start Disabled | Data | Yes / No | No |