The following DTC is for the batteries located in the generator battery carrier:
P0A7E is for the hybrid battery pack overtemperature.
Battery temperature sensors allow the generator battery control module to monitor the temperature of the batteries in the generator battery carrier. The module applies 5 volts to internal input resistors that are connected to the signal circuits of the battery temperature sensors. The module provides ground to the battery temperature sensors through the low reference circuit. The generator battery control module monitors the voltage drops across the battery temperature sensors and uses the inputs for hybrid calculations. When the battery temperatures are cold, the resistances of the sensors are high and the voltage signals are high. When the battery temperatures are hot, the resistances of the sensors are low and the voltage signals are low.
This diagnostic procedure supports the following DTC:
DTC P0A7E Hybrid Battery Pack Overtemperature
The ignition is ON.
The generator battery control module determines that the value of the battery temperature parameter is greater than 55°C (131°F).
• | The control module stores the DTC information into memory when the diagnostic runs and fails. |
• | The malfunction indicator lamp (MIL) will not illuminate. |
• | The control module records the operating conditions at the time the diagnostic fails. The control module stores this information in the Failure Records. |
• | The driver information center, if equipped, may display a message. |
• | The DTC will become history if the generator battery control module no longer detects a fault. |
• | The history DTC will clear after 100 fault-free ignition cycles. |
• | The DTC can be cleared with a scan tool. |
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
Schematic Reference: Hybrid Energy Storage Schematics Connector End View Reference: Hybrid Energy Storage Connector End Views | ||||
1 | Did you perform the Diagnostic System Check - Vehicle? | -- | Go to Step 2 | |
2 |
Does the scan tool indicate that the Battery 1,2,3 Temperature parameters are greater than the specified value? | 55°C (131°F) | Go to Step 3 | Go to Testing for Intermittent Conditions and Poor Connections |
3 | Does the scan tool indicate that the DTC P0A82 is set current? | -- | Go to DTC P0A83 | Go to Step 4 |
4 | Inspect the generator battery carrier fan ducts for obstructions. Clean or replace as necessary. Refer to Battery Cooling Air Inlet Duct Replacement . Did you find and correct the condition? | -- | Go to Step 5 | -- |
5 |
Does the DTC reset? | -- | Go to Step 2 | System OK |