Removal Procedure
Notice: In order to avoid actuator damage, DO NOT apply power to the actuator when it is not installed in the HVAC module.
- Remove the center console, if equipped. Refer to
Console Replacement
.
- Remove the instrument panel (I/P) insulator panel. Refer to
Instrument Panel Insulator Replacement
.
- Disconnect the electrical connector (1) from the left air temperature actuator (2).
- Remove the screws from the left air temperature actuator (2).
- Remove the left air temperature actuator (2) from the HVAC module assembly (3).
Installation Procedure
- Install the left air temperature actuator (2) to the HVAC module assembly (3).
Notice: Refer to Fastener Notice in the Preface section.
- Install the screws to the left air temperature actuator (2).
Tighten
Tighten the screws to 2 N·m (18 lb ft).
- Install the electrical connector (1) to the left air temperature actuator (2).
- Install the I/P insulator panel. Refer to
Instrument Panel Insulator Replacement
.
- Install the center console, if equipped. Refer to
Console Replacement
.
- Reprogram the left air temperature actuator. Refer to
Actuator Recalibration
.