Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Driver Seat Schematics and Passenger Seat Schematics Connector End View Reference: Power Seat Connector End Views | |||
1 | Did you review the Lumbar System Description and Operation and perform the necessary inspections? | Go to Step 2 | Go to Symptoms - Power Seats |
2 | Verify the condition is present. Does the system operate normally? | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 3 |
3 |
Does the test lamp illuminate when the switch is operated in both directions? | Go to Step 6 | Go to Step 4 |
4 | Test the motor control circuits for an open or short to ground. Refer to Circuit Testing and to Wiring Repairs . Did you find and correct the condition? | Go to Step 9 | Go to Step 5 |
5 | Inspect for poor connections at the lumbar switch. Refer to Testing for Intermittent Conditions and Poor Connections and to Connector Repairs . Did you find and correct the condition? | Go to Step 9 | Go to Step 7 |
6 | Inspect for poor connections at the inoperative lumbar or torso motor. Refer to Testing for Intermittent Conditions and Poor Connections and to Connector Repairs . Did you find and correct the condition? | Go to Step 9 | Go to Step 8 |
7 | Replace the lumbar switch. Refer to Lumbar Switch Replacement . | Go to Step 9 | -- |
8 | Replace the lumbar support/torso bolster motor assembly. Refer to Front Seat Lumbar Support Replacement . Is the repair complete? | Go to Step 9 | -- |
9 | Operate the system to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Driver Seat Schematics Connector End View Reference: Power Seat Connector End Views | |||
1 | Did you perform the Diagnostic System Check - Vehicle? | Go to Step 2 | |
2 | Verify the condition is present. Does the system operate normally? | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 3 |
3 |
Do any of the Lumbar or Torso Switch parameters display Active? | Go to Step 4 | Go to Step 5 |
4 | Disconnect the lumbar adjuster switch connector. Do all of the Lumbar or Torso Switch parameters display Inactive? | Go to Step 18 | Go to Step 13 |
5 |
Does the scan tool display the lumbar forward switch as active? | Go to Step 6 | Go to Step 9 |
6 |
Does the scan tool display the lumbar rearward switch as active? | Go to Step 7 | Go to Step 10 |
7 |
Does the scan tool display the torso inward switch as active? | Go to Step 8 | Go to Step 11 |
8 |
Does the scan tool display the torso outward switch as active? | Go to Step 19 | Go to Step 12 |
9 |
Does the scan tool display the lumbar forward switch as Active? | Go to Step 18 | Go to Step 14 |
10 |
Does the scan tool display the lumbar rearward switch as Active? | Go to Step 18 | Go to Step 15 |
11 |
Does the scan tool display the torso inward switch as Active? | Go to Step 18 | Go to Step 16 |
12 |
Does the scan tool display the torso outward switch as Active? | Go to Step 18 | Go to Step 17 |
13 | Test the active lumbar or torso switch signal circuit for a short to voltage. Refer to Circuit Testing and to Wiring Repairs . Did you find and correct the condition? | Go to Step 22 | Go to Step 19 |
14 | Test the lumbar forward switch signal circuit for an open or high resistance. Refer to Circuit Testing and to Wiring Repairs . Did you find and correct the condition? | Go to Step 22 | Go to Step 19 |
15 | Test the lumbar rearward switch signal circuit for an open or high resistance. Refer to Circuit Testing and to Wiring Repairs . Did you find and correct the condition? | Go to Step 22 | Go to Step 19 |
16 | Test the torso inward switch signal circuit for an open or high resistance. Refer to Circuit Testing and to Wiring Repairs . Did you find and correct the condition? | Go to Step 22 | Go to Step 19 |
17 | Test the torso outward switch signal circuit for an open or high resistance. Refer to Circuit Testing and to Wiring Repairs . Did you find and correct the condition? | Go to Step 22 | Go to Step 19 |
18 | Inspect for poor connections at the harness connector of the lumbar switch assembly. Refer to Testing for Intermittent Conditions and Poor Connections and to Connector Repairs . Did you find and correct the condition? | Go to Step 22 | Go to Step 20 |
19 | Inspect for poor connections at the harness connector of the DSM . Refer to Testing for Intermittent Conditions and Poor Connections and to Connector Repairs . Did you find and correct the condition? | Go to Step 22 | Go to Step 21 |
20 | Replace the lumbar switch assembly. Refer to Lumbar Switch Replacement . Did you complete the replacement? | Go to Step 22 | -- |
21 | Replace the DSM. Refer to Control Module References for replacement, setup, and programming. Did you complete the replacement? | Go to Step 22 | -- |
22 | Operate the system to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |