• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Rear Defogger Battery Supply | 1 | 1 | -- | -- |
Rear Defogger Relay Control | B0283 06 | B0283 06 | 2 | -- |
Rear Defogger Element Supply | 1 | 1 | 2 | -- |
Rear Defogger Relay Coil Ground | -- | B0283 06 | -- | -- |
Rear Defogger Element Ground | -- | 1 | -- | -- |
1. Rear Defogger Inoperative 2. Rear Defogger Always ON |
The HVAC control module controls the rear window defroster through the REAR DEFOG relay located in the underhood fuse block. When the rear defroster is activated the HVAC control module supplies battery voltage through the defroster relay control circuit to energize the relay coil.
Window Systems Connector End Views
Rear Window Defogger Description and Operation
⇒ | If the indicator does not illuminate when system operation is attempted, replace the HVAC control module. |
⇒ | If the test lamp does not illuminate test the battery supply circuit to the REAR DEFOG relay for an open/high resistance or short to ground. If the circuit tests normal replace the REAR DEFOG relay. |
⇒ | If the test lamp does not illuminate repair the ground circuit for an open/high resistance. |
⇒ | If the test lamp does not illuminate repair the defogger grid supply circuit for an open/high resistance. |
⇒ | If the test lamp remains bright at the middle of the grid line, test for an open between the test point and the ground side of the grid. |
⇒ | If the test lamp remains off at the middle of the grid line, test for an open between the test point and the voltage supply side of the grid. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for HVAC control module replacement, programming, and setup |