Diagnostic Instructions
Circuit Description
The instrument panel cluster (IPC) illuminates the StabiliTrak indicator during the IPC bulb check or when the electronic brake control module (EBCM) detects a fault and sends a serial data message to the IPC commanding the indicator ON.
Reference Information
Schematic Reference
Antilock Brake System Schematics
Connector End View Reference
Component Connector End Views
Description and Operation
ABS Description and Operation
Electrical Information Reference
Scan Tool Reference
Control Module References for scan tool information
Circuit/System Verification
- Ignition ON, with a scan tool command the IPC display test ON and OFF. The StabiliTrak indicator should turn ON and OFF.
⇒ | If the indicator does not turn ON and OFF, replace the IPC. |
- Observe the scan tool BCM Traction Control Switch parameter while pressing and releasing the traction control switch. The reading should change between Active and Inactive.
Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the traction control switch.
- Test for less than 1 ohm between the ground circuit terminal 3 and ground.
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
- Ignition ON, verify the scan tool Traction Control Switch parameter is Inactive.
⇒ | If not the specified value, test the signal circuit terminal 1 for a short to ground. If the circuit tests normal, replace the BCM. |
- Install a 3A fused jumper wire between the signal circuit terminal 1 and the ground circuit terminal 3. Verify the scan tool Traction Control Switch parameter is Active.
⇒ | If not the specified value, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the BCM. |
- If all circuits test normal, test or replace the traction control switch.
Component Testing
- Ignition OFF, disconnect the harness connector at the traction control switch.
- Test for infinite resistance between the signal terminal 3 and the ground terminal 1 with the switch in the open position.
⇒ | If not the specified value, replace the traction control switch. |
- Test for less than 3 ohms between the signal terminal 3 and the ground terminal 1 with the switch in the closed position.
⇒ | If greater than the specified range, replace the traction control switch. |
Repair Instructions
Perform the