Air Conditioning Cycling Switch Replacement Non-HP2
Removal Procedure
- Disconnect the electrical connector from the A/C low pressure switch.
- Remove the A/C low pressure switch from the accumulator.
- Remove the O-ring and discard.
Installation Procedure
- Install the new O-ring seal to the switch. Refer to
O-Ring Replacement.
Caution: Refer to Fastener Caution in the Preface section.
- Install the A/C low pressure switch to the accumulator and tighten to
6 N·m (53 lb in).
- Connect the electrical connector to the A/C low pressure switch.
- Leak test the fittings of the components using the
J 39400-A .