• | Perform the Diagnostic System Check - Vehicle prior to using the diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
I/P Module Disable Switch Signal | -- | B0098 52 | B0098 52 | -- |
I/P Module Enable Switch Signal | B0098 52 | B0098 52 | B0098 52 | -- |
Ignition 1 Voltage | B1370 06 | B0098 52 | -- | -- |
The inflatable restraint I/P module disable switch is ignition key operated to manually enable or disable the inflatable restraint I/P module. When the ignition is turned ON, ignition 1 voltage is supplied to the inflatable restraint I/P module disable switch and based on the position of the switch either the I/P module disable switch signal circuit (ON) or the I/P module suppression indicator control (OFF) circuit will be active to the inflatable restraint sensing and diagnostic module (SDM). The SDM will communicate to the instrument panel cluster (IPC) to illuminate the appropriate the ON/OFF indicator as well as enable or disable the deployment of the I/P module. If a malfunction is detected, a DTC will be stored.
Ignition 1 voltage is between 9-16 volts.
The SDM detects both the I/P module disable switch signal circuit (ON) and the I/P module suppression indicator control (OFF) circuit active or inactive for 500 milliseconds.
The SDM requests the IPC to illuminate the AIRBAG indicator.
• | The condition for setting the DTC no longer exists. |
• | A history DTC will clear once 100 malfunction-free ignition cycles have occurred. |
SIR System Description and Operation
Control Module References for scan tool information
Important: When removing the connectors inspect for damage or corrosion. Damage or corrosion to the following requires repair or replacement of the affected component/connector:
• Inflatable restraint I/P module disable switch • SDM • Inflatable restraint I/P module wiring harness connector • SDM wiring harness connector
⇒ | If the test lamp does not illuminate, test the ignition circuit for a short to ground or an open/high resistance, if the circuit tests normal and the ignition fuse is open, test or replace the inflatable restraint I/P module disable switch. |
⇒ | If the test lamp does not illuminate, test the control circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the SDM. |
⇒ | If less than the specified value, inflatable restraint I/P module disable switch. |
⇒ | If not the specified range, replace the inflatable restraint I/P module disable switch. |
⇒ | If not the specified range, replace the inflatable restraint I/P module disable switch. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for SDM replacement, setup, and programming |