Danger: Always perform the High Voltage Disabling procedure prior to servicing any High
Voltage component or connection. Personal Protection Equipment (PPE) and proper procedures must be followed.
The High Voltage Disabling procedure will perform the following tasks:
• | Identify how to disable high voltage. |
• | Identify how to test for the presence of high voltage. |
• | Identify condition under which high voltage is always present and personal protection equipment (PPE) and proper procedures must be followed. |
Failure to follow the procedures exactly as written may result in serious injury or death.
Preliminary Procedures
- Disable the high voltage at the drive motor generator battery. Refer to
High Voltage Disabling.
- Remove the upper, front, and right cover. Refer to
Drive Motor Battery Case Upper Cover, Front Cover, and Right Side Cover Replacement.
- Remove the drive motor battery high voltage manual disconnect knob housing. Refer to
Drive Motor Battery High Voltage Manual Disconnect Knob Housing Replacement.
- Remove the battery cooling air outlet duct assembly. Refer to
Drive Motor Battery Cooling Air Outlet Duct and Front Air Outlet Duct Replacement.
|