Step
| Action
| Value(s)
| Yes
| No
|
1
| Did you perform the Power Windows
System Check?
| --
| Go to
Step 2
| Go
to
Power Windows System Check
|
2
|
- Access the left door lock and side window switch.
- Turn the ignition switch to the RUN position.
- Connect a J 39200
digital multimeter (DMM) to ground and CKT 1001 (DK GRN), terminal L
at the left door lock and side window switch connector C1.
- Ensure that the connector C1 remains connected.
- Test for voltage.
Is ignition voltage present?
| IGN+
| Go to
Step 4
| Go to
Step 3
|
3
| Repair the open or high resistance in CKT 1001 (DK GRN) between
the power window circuit breaker and the left door lock and side window switch.
Is the repair complete?
| --
| Go to
Power Windows System Check
| --
|
4
|
- Turn the ignition switch to the RUN position.
- Connect a J 39200
DMM to CKT 1001 (DK GRN), terminal L at the left door
lock and side window switch connector C1 and CKT 1850 (BLK),
terminal C at the left door lock and side window switch connector C2.
- Test for voltage.
Is ignition voltage present?
| IGN+
| Go to
Step 6
| Go to
Step 5
|
5
| Repair the open or high resistance in CKT 1850 (BLK) between
the left door lock and side window switch connector C2 and G202.
Is the repair complete?
| --
| Go to
Power Windows System Check
| --
|
6
|
- Turn the ignition switch to the RUN position.
- Connect a J 39200
DMM to CKT 164 (DK BLU), terminal A and CKT 165
(BRN), terminal E at the left door lock and side window switch connector C2.
- Ensure that the connector C2 remains connected.
- Operate the left side window regulator switch in the UP/DOWN position.
- Test for voltage.
- Connect the J 39200
DMM to CKT 166 (LT BLU), terminal B and CKT 167
(TAN), terminal D at the left door lock and side window switch connector C2.
- Ensure that the connector C2 remains connected.
- Operate the right side window regulator switch in the UP/DOWN
position.
- Test for voltage.
Is ignition voltage present?
| IGN+
| Go to
Step 8
| Go to
Step 7
|
7
| Replace the left door lock and side window switch.
Is the repair complete?
| --
| Go to
Power Windows System Check
| --
|
8
|
- Turn the ignition switch to the RUN position.
- Connect a J 39200
DMM to CKT 164 (DK BLU), terminal B at the left front
side window regulator motor and CKT 165 (BRN), terminal E
at the left door lock and side window switch connector C2.
- Ensure that the connector C2 remains connected.
- Operate the left side window regulator switch in the UP position.
- Test for voltage.
Is ignition voltage present?
| IGN+
| Go to
Step 10
| Go to
Step 9
|
9
| Repair the open or high resistance in CKT 164 (DK BLU) between
the left door lock and side window switch and the left side window regulator
motor.
Is the left side window regulator now operational?
| --
| Go to
Step 15
| Go to
Step 10
|
10
|
- Turn the ignition switch to the RUN position.
- Connect a J 39200
DMM to CKT 164 (DK BLU), terminal A at the left door
lock and side window switch connector C2 and CKT 165 (BRN),
terminal A at the left side window regulator motor connector.
- Ensure that the connectors remain connected.
- Operate the left side window regulator switch in the DOWN position.
- Test for voltage.
Is ignition voltage present?
| IGN+
| Go to
Step 12
| Go to
Step 11
|
11
| Repair the open or high resistance in CKT 165 (BRN) between the
left door lock and side window switch and the left side window regulator
motor.
Is the left side window regulator now operational?
| --
| Go to
Step 15
| Go to
Step 12
|
12
| Inspect for a poor connection at the left side window regulator
motor.
Is the connection OK?
| --
| Go to
Step 14
| Go to
Step 13
|
13
| Repair the connection as necessary.
Is the left side window regulator now operational?
| --
| Go to
Step 15
| Go to
Power Windows System Check
|
14
| Replace the left side window regulator
motor. Refer to
Power Window Motor Replacement
.
Is the left side window regulator now operational?
| --
| Go to
Step 15
| Go to
Power Windows System Check
|
15
|
- Access the right door lock and window switch.
- Turn the ignition switch to the RUN position.
- Connect a J 39200
DMM to CKT 166 (LT BLU), terminal J at the right door
lock and window switch connector C1 and ground.
- Ensure that the right door lock and window switch connector C1
remains connected.
- Operate the right side window regulator motor at the left door
lock and side window switch in the UP position.
- Test for voltage.
Is ignition voltage present?
| IGN+
| Go to
Step 17
| Go to
Step 16
|
16
| Repair the open or high resistance in CKT 166 (LT BLU) between
the left door lock and side window switch and the right door lock and window
switch connector.
Is the repair complete?
| --
| Go to
Power Windows System Check
| --
|
17
|
- Turn the ignition switch to the RUN position.
- Connect a J 39200
DMM to CKT 167 (TAN), terminal L at the right door lock
and window switch connector C1 and ground.
- Ensure that the right door lock and window switch connector C1
remains connected.
- Operate the right side window regulator motor at the left door
lock and side window switch in the DOWN position.
- Test for voltage.
Is ignition voltage present?
| IGN+
| Go to
Step 19
| Go to
Step 18
|
18
| Repair the open or high resistance in CKT 167 (TAN) between the
left door lock and side window switch and the right door lock and side window
switch.
Is the repair complete?
| --
| Go to
Power Windows System Check
| --
|
19
|
- Turn the ignition switch to the RUN position.
- Connect a J 39200
DMM to CKT 667 (BRN), terminal K and CKT 666
(DK BLU), terminal G at the right door lock and window switch connector C1.
- Ensure that the connector C1 remains connected.
- Operate the right side window regulator motor from the left door
lock and side window switch in the UP/DOWN position.
- Test for voltage.
Is ignition voltage present?
| IGN+
| Go to
Step 23
| Go to
Step 20
|
20
| Inspect for a poor connection at the right door lock and window switch.
Is the connection OK?
| --
| Go to
Step 22
| Go to
Step 21
|
21
| Repair the connection as necessary.
Is the repair complete?
| --
| Go to
Power Windows System Check
| --
|
22
| Replace the right door lock and window switch. Refer to
Front Side Door Window Switch Replacement
.
Is the repair complete?
| --
| Go to
Power Windows System Check
| --
|
23
|
- Turn the ignition switch to the RUN position.
- Connect a J 39200
DMM to CKT 667 (BRN), terminal K at the right door lock
and window switch connector C1 and CKT 666 (DK BLU), terminal B
at the right window regulator motor connector.
- Ensure that the connectors remain connected.
- Operate the right side window regulator motor from the left door
lock and side window switch in the UP position.
- Test for voltage.
Is Ignition voltage present?
| IGN+
| Go to
Step 25
| Go to
Step 24
|
24
| Repair the open or high resistance in CKT 666 (DK BLU) between
the right door lock and side window switch and the right window regulator
motor connectors.
Is the repair complete?
| --
| Go to
Power Windows System Check
| --
|
25
|
- Turn the ignition switch to the RUN position.
- Connect a J 39200
DMM to CKT 667 (BRN), terminal A and CKT 666
(DK BLU), terminal B at the right window regulator motor connector.
- Ensure that the connector remains connected.
- Operate the right side window regulator motor from the left door
lock and side window switch in the DOWN position.
- Test for voltage.
Is Ignition voltage present?
| IGN+
| Go to
Step 27
| Go to
Step 26
|
26
| Repair the open or high resistance in CKT 667 (BRN) between the
right door lock and side window switch and the right window regulator motor.
Is the repair complete?
| --
| Go to
Power Windows System Check
| --
|
27
| Inspect for a poor connection at the right door window regulator motor.
Is the connection OK?
| --
| Go to
Step 29
| Go to
Step 28
|
28
| Repair the connection as necessary.
Is the repair complete?
| --
| Go to
Power Windows System Check
| --
|
29
| Replace the right door window regulator motor. Refer to
Power Window Motor Replacement
.
Is the repair complete?
| --
| Go to
Power Windows System Check
| --
|