Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Cigar Lighter/Auxiliary Outlets System Check? | -- | Go to Step 2 | |
2 | Connect a test lamp from the cigar lighter connector cavity A to ground. Did the test lamp light? | -- | Go to Step 4 | Go to Step 3 |
3 | Repair the open or high resistance in CKT 640 (ORN) between the IP fuse block and the cigar lighter. Refer to Wiring Repairs . Is the repair complete? | -- | -- | |
4 | Connect the test lamp from the cigar lighter connector cavity A to cavity B. Did the test lamp light? | -- | Go to Step 5 | Go to Step 6 |
5 | Replace the cigar lighter. Is the repair complete? | -- | -- | |