The inside air temperature sensor is a thermistor used in order to control the signal voltage in the electronic climate control (ECC) module. The ECC module supplies a reference voltage (about 5 volts) on CKT 734 to the sensor. When the inside air temperature is cold, the thermistor resistance is high. Therefore, the ECC module will receive a high voltage input. If the outside air temperature is hot, the thermistor resistance is low. Therefore, the ECC module will receive a low signal voltage input. Refer to Sensor Resistance Table .
When the ignition is ON, the ECC module will detect the DTC B0165 any time that CKT 734 is at or near zero voltage.
The ECC module will use a default value of 23.8°C (75°F) or 88 A/D counts until the fault is cleared.
This fault will clear as soon as the fault goes away or has been repaired. The system will then return to normal operation. History DTCs may only be cleared by removing and restoring B+ or by using the scan tool.
• | The ECC module may set class 2 lost communication DTCs when the body control module (BCM) or the vehicle control module (VCM) is being reprogrammed After reprogramming, inspect for DTCs in the ECC module. Clear any history U DTCs, then resume diagnostics. |
• | Visually inspect the sensor connector and harness for corrosion and damage. The resistance value of the sensor must be 300-170,000 ohms. If the resistance is not within specifications, replace the sensor. |
The numbers below refer to the step numbers on the diagnostic table.
This step measures the resistance of the inside air temperature sensor.
This step inspects for a short to ground in CKT 734 (DK GRN).
This step inspects for intermittents and tests for a malfunctioning ECC module.
This step repairs the short to ground in CKT 734 (DK GRN).
This step replaces a defective inside air temperature sensor.
This step replaces a defective ECC module.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Diagnostic System Check? | -- | Go to Step 2 | Go to Diagnostic System Check |
Is the resistance within the range specified in the table? | -- | Go to Step 3 | Go to Step 6 | |
Is continuity present? | -- | Go to Step 5 | Go to Step 4 | |
Does the DTC reset? | -- | Go to Step 7 | Go to Intermittents and Poor Connections Diagnosis in Wiring Systems | |
Repair the short to ground in CKT 734 (DK GRN). Is the repair complete? | -- | Go to Diagnostic System Check | -- | |
Replace the inside air temperature sensor. Refer to Inside Air Temperature Sensor Replacement . Is the replacement complete? | -- | Go to Diagnostic System Check | -- | |
Replace the ECC module. Refer to Control Assembly Replacement . Is the replacement complete? | -- | Go to Diagnostic System Check | -- |