Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Automatic Day-Night Mirrors System Check? | -- | Go to Step 2 | |
2 |
Is the fuse blown? | -- | Go to Step 3 | Go to Step 6 |
3 | Test CKT 341 (BRN) for a short to ground between the IP fuse block and cavity 1 of the automatic day/night inside mirror. Is a short present? | -- | Go to Step 4 | Go to Step 5 |
4 | Repair the short to ground in CKT 341 (BRN). Is the repair complete? | -- | -- | |
5 | Replace the 10A HVAC fuse in the UBEC. Is the repair complete? | -- | -- | |
6 |
Does the test lamp light? | -- | Go to Step 8 | Go to Step 7 |
7 | Repair the open in CKT 341 (BRN) between the IP fuse block and cavity 1 of the automatic day/night inside mirror. Is the repair complete? | -- | -- | |
8 | Connect a test lamp between B+ and cavity 2 of the automatic day/night inside rear view mirror. Does the test lamp light? | -- | Go to Step 9 | Go to Step 10 |
9 | Replace the automatic day/night inside rear view mirror. Refer to Inside Rearview Mirror Replacement . Is the repair complete? | -- | -- | |
10 | Repair the open in CKT 1850 (BLK) between the automatic day/night inside rear view mirror and G202. Is the repair complete? | -- | -- |