Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
DEFINITION: The lift window release system does not operate by remote or with the lock cylinder switch. | ||||
1 | Did you perform the Lift Window Release System Check? | -- | Go to Step 2 | |
2 | Is the MIR/LKS fuse in the IP fuse block open? | -- | Go to Step 3 | Go to Step 12 |
3 |
Is a short or low resistance present? | -- | Go to Step 4 | Go to Step 5 |
4 | Locate and repair a short to ground in CKT 840. Is the repair complete? | -- | -- | |
5 |
Is a short or low resistance present? | -- | Go to Step 6 | Go to Step 7 |
6 | Locate and repair a short to ground in CKT 1221 (WHT/BLK). Is the repair complete? | -- | -- | |
7 |
Is a short or low resistance present? | -- | Go to Step 8 | Go to Step 9 |
8 | Locate and repair a short to ground in CKT 56 (BLK/WHT). Is the repair complete? | -- | -- | |
9 |
Is continuity present? | -- | Go to Step 10 | Go to Step 11 |
10 | Replace the BBEC. Is the repair complete? | -- | -- | |
11 | Replace the liftglass relay. Is the repair complete? | -- | -- | |
12 |
Is voltage present? | Battery Voltage | Go to Step 15 | Go to Step 13 |
13 |
Is voltage present? | Battery Voltage | Go to Step 15 | Go to Step 14 |
14 | Locate and repair an open in CKT 56 (BLK/WHT). Is the repair complete? | -- | -- | |
15 |
Is voltage present? | Battery Voltage | Go to Step 17 | Go to Step 16 |
16 | Locate and repair an open in CKT 1350 (BLK). Is the repair complete? | -- | -- | |
17 | Replace the lift window release actuator. Is the repair complete? | -- | -- |