Important: Do not bend the water outlet adapter pipe out of the way in order to remove the valve rocker arm cover.
13.1. | Loosen the bolt at the rear of the cylinder head. |
13.2. | Remove the two bolts that secure the bracket to the valve rocker arm cover. |
13.3. | Slide the bracket off of the bolt at the rear of the cylinder head. |
Important: The valve rocker arm cover gasket is reusable. Only replace the valve rocker arm cover gasket if it is damaged.
Notice: Refer to Fastener Notice in the Preface section.
Tighten
Tighten the air cleaner outlet resonator bracket bolts to 10 N·m (89 lb in).
4.1. | Slide the bracket over the bolt at the rear of the cylinder head. |
4.2. | Install the two bolts that secure the bracket to the valve rocker arm cover. |
Tighten
Tighten
Tighten the bolts to 25 N·m (18 lb ft).