Removal Procedure
- Remove the air cleaner outlet duct. Refer to
Air Cleaner Outlet Duct Replacement
.
- Remove the EGR pipe bracket
retaining fastener.
- Loosen the pipe fittings at both ends of the EGR pipe.
- Remove the EGR pipe.
Installation Procedure
- Install the EGR pipe in
the proper location and start the pipe fittings by hand. Do not fully tighten
at this step.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Ensure that the
EGR pipe fittings are correctly lined up on the adaptors to the exhaust and
intake manifolds.
Tighten
- Tighten the EGR pipe fitting to exhaust manifold to 30 N·m (22 lb ft).
- Tighten the EGR pipe fitting to intake manifold to 25 N·m (18 lb ft).
- Install the EGR pipe bracket retaining fastener.
Tighten
Tighten the fastener to 25 N·m (18 lb ft).
- Install the air cleaner outlet duct. Refer to
Air Cleaner Outlet Duct Replacement
.