Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Diagnostic System Check? | -- | Go to Step 2 | Go to Diagnostic System Check |
2 | Verify that the A/C system does not maintain the set temperature. Does the A/C system operate normally? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Is voltage present in CKT 341 (BRN)? | 9-16 V | Go to Step 4 | Go to Step 5 |
4 | Repair the open in CKT 341 (BRN). Is the repair complete? | -- | Go to Step 8 | -- |
5 |
Is an open present in CKT 1850 (BLK)? | -- | Go to Step 6 | Go to Step 7 |
6 | Repair the open in CKT 1850 (BLK). Is the repair complete? | -- | Go to Step 8 | -- |
7 | Replace the inside air temperature sensor. Refer to Inside Air Temperature Sensor Replacement . Is the replacement complete? | -- | Go to Step 8 | -- |
8 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |