Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Lighting Systems Diagnostic System Check? | -- | Go to Step 2 | |
2 | Verify that the IP compartment lamp is inoperative. Does the IP compartment lamp operate normally? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Does the test lamp light? | -- | Go to Step 5 | Go to Step 4 |
4 | Locate and repair the open or high resistance in CKT 1732 (ORN). Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 9 | -- |
5 | Connect a test lamp between the IP compartment lamp cavity A and cavity B. Refer to Circuit Testing in Wiring Systems. Does the test lamp light? | -- | Go to Step 8 | Go to Step 6 |
6 | Inspect for an open or high resistance in CKT 1050 (BLK). Refer to Circuit Testing in Wiring Systems. Does an open exist? | -- | Go to Step 7 | Go to Step 8 |
7 | Repair the open or high resistance in CKT 1050 (BLK). Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 9 | -- |
8 | Test the Bulb for an open filament and replace if necessary. Replace the IP compartment lamp assembly if the bulb tests good. Refer to Instrument Panel Compartment Lamp Replacement . Is the repair complete? | -- | Go to Step 9 | -- |
9 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |