Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Power Door Systems Diagnostic System Check? | -- | Go to Step 2 | |
2 | Verify that the RR power window is inoperative from the RR side window switch. Do the power windows operate normally? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Is battery voltage present? | B+ | Go to Step 4 | Go to Step 6 |
4 |
Is ignition voltage present? | B+ | Go to Step 5 | Go to Step 8 |
5 |
Is ignition voltage present? | B+ | Go to Step 9 | Go to Step 7 |
6 | Locate and repair the open or the high resistance in CKT 1001 (DK GRN). Refer to Wiring Repairs in wiring systems. Is the repair complete? | -- | Go to Step 10 | -- |
7 | Locate and repair the open or the high resistance in CKT 1307 (DK BLU). Refer to Wiring Repairs in wiring systems. Is the repair complete? | -- | Go to Step 10 | -- |
8 | Replace the side window lockout switch. Is the repair complete? | -- | Go to Step 10 | -- |
9 | Replace the RR side window switch. Refer to Front Side Door Window Switch Replacement Is the repair complete? | B+ | Go to Step 10 | |
10 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |