Step
| Action
| Value(s)
| Yes
| No
|
DEFINITION: Perform this test in order to verify the automatic level
control air compressor performance and to identify and repair the
potential leaks in the automatic level control air compressor assembly.
|
1
|
- Disconnect the electrical connection to the automatic level control
air compressor assembly.
- Disconnect the air line from the automatic level control air dryer.
- Connect the automatic level control air dryer to the J 22124-B
(using the adapter J 22124-98)
on the side opposite of the toggle valve. Close the toggle valve (down position).
- Using the fused jumper wire, connect the automatic level control
ignition 1 voltage circuit and battery positive voltage circuit to a 12 V+
source, and the automatic level control relay coil supply voltage circuit
and automatic level control ground circuit to ground. This step will activate
the automatic level control compressor motor.
- Allow the automatic level control air compressor to run until
the J 22124-B
gauge pressure
reads at least 750 kPa (110 psi).
- Disconnect the power supply to the automatic level control air
compressor.
Important: The automatic level control air compressor may leak down as low as
620 kPa (90 psi) after disconnecting the power. This is an
acceptable level.
Does the automatic level control air compressor develop at least 750 kPa
(110 psi)?
| --
| Go to
Step 5
| Go to
Step 2
|
2
|
- Apply service air to the J 22124-B
service valve until the gauge reads 690 kPa (100 psi).
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Using a soap
bubble solution, check for leaks in the automatic level control air compressor
assembly:
• | The automatic level control air dryer O-ring casting
bore (1). |
• | The automatic level control air compressor head cover bolts (3). |
Tighten Tighten the automatic level control air compressor head cover bolts
as required to 6 N·m (53 lb in).
• | Around the edge of the cover gasket (6). If you find a leak, check
the tightness of the cover bolts before you replace the gasket. |
- Complete repairs as necessary.
Did you find and repair any leaks?
| --
| Go to
Step 3
| Go to
Step 4
|
3
| Re-apply the service air and monitor the automatic level control air
compressor assembly for leaks.
Does the pressure leak down below 620 kPa (110 psi)?
| --
| Go to
Step 4
| System OK
|
4
|
- Replace the automatic level control air compressor. Refer to
Air Compressor Replacement
.
- Perform automatic level control system operation check to verify
the repair. Refer to
Automatic Level Control System Operation Check
.
Was the repair completed?
| --
| Go to
Step 5
| --
|
5
| Monitor the J 22124-B
pressure gauge for 1 minute.
Does the pressure leak down below 620 kPa (90 psi)?
| --
| Go to
Step 2
| System OK
|