Table 1: | A/C Performance Table |
This test measures the operating efficiency of the A/C system under the following conditions:
• | The current ambient air temperature |
• | The current relative humidity |
• | The high side pressure of the A/C system |
• | The low side pressure of the A/C system |
• | The temperature of the air being discharged into the passenger compartment |
The numbers below refer to the step numbers on the diagnostic table.
This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
This step measures the performance of the A/C system.
This step is to allow for vehicle variations as well as high ambient temperatures.
Step | Action | Values | Yes | No | ||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Important:
| ||||||||||||||||||||||||||||
Are both the low side and high side pressures within the specified value? | More than 16°C (60°F) - 345 kPa (50 psi) More than 24°C (75°F) - 483 kPa (70 psi) More than 33°C (90°F) - 690 kPa (100 psi) | Go to Step 2 | Go to Leak Testing | |||||||||||||||||||||||||
Important: Record the relative humidity and the ambient air temperature at the time of the test.
Important: Press the RESET button, before using the print function of the J 43600 .
Does all the data recorded fall within the specified ranges of the A/C performance table? | -- | Go to Step 4 | Go to Step 3 | |||||||||||||||||||||||||
If the pressures and temperatures recorded do not fall within the specified ranges:
Does all the data recorded fall within the specified ranges of the A/C performance table? | -- | Go to Step 8 | Go to Step 4 | |||||||||||||||||||||||||
4 | Do the high and low side pressures fall within the specified ranges, but the outlet temperatures do not? | -- | Go to Step 5 | |||||||||||||||||||||||||
5 | Is the low side pressure greater than the specified range, but the high side pressure within or less than the specified range? | -- | Go to Step 6 | |||||||||||||||||||||||||
6 | Are the low and high side pressures both greater than the specified ranges? | -- | Go to Step 7 | |||||||||||||||||||||||||
7 | Is the high side pressure greater than the specified range, but the low side pressure is within or less than the specified range? | -- | Go to Step 8 | |||||||||||||||||||||||||
8 | Operate the system in order to verify the test results. Did you find the same results? | -- | System OK |
Ambient Air Temperature | Relative Humidity | Service Port Pressure | Maximum Left Center Discharge Air Temperature | |
---|---|---|---|---|
Low Side | High Side | |||
13-18°C (55-65°F) | 0-100% | 145-186 kPa (21-27 psi) | 931-1207 kPa (135-175 psi) | 6°C (43°F) |
19-24°C (66-75°F) | Below 40% | 172-214 kPa (25-31 psi) | 1103-1379 kPa (160-200 psi) | 7°C (45°F) |
Above 40% | 172-214 kPa (25-31 psi) | 1172-1448 kPa (170-210 psi) | 8°C (46°F) | |
25-29°C (76-85°F) | Below 35% | 179-221 kPa (26-32 psi) | 1034-1310 kPa (150-190 psi) | 9°C (48°F) |
35-60% | 186-228 kPa (27-33 psi) | 1103-1379 kPa (160-200 psi) | 10°C (50°F) | |
Above 60% | 193-234 kPa (28-34 psi) | 1103-1379 kPa (160-200 psi) | 9°C (49°F) | |
30-35°C (86-95°F) | Below 30% | 241-283 kPa (35-41 psi) | 1379-1655 kPa (200-240 psi) | 13°C (55°F) |
30-50% | 241-283 kPa (35-41 psi) | 1379-1655 kPa (200-240 psi) | 13°C (56°F) | |
Above 50% | 255-296 kPa (37-43 psi) | 1379-1655 kPa (200-240 psi) | 14°C (57°F) | |
36-41°C (96-105°F) | Below 20% | 255-310 kPa (37-45 psi) | 1655-1931 kPa (240-280 psi) | 16°C (60°F) |
20-40% | 283-338 kPa (41-49 psi) | 1689-1965 kPa (245-285 psi) | 18°C (64°F) | |
Above 40% | 310-365 kPa (45-53 psi) | 1724-1827 kPa (250-265 psi) | 16°C (61°F) | |
42-46°C (106-115°F) | Below 20% | 303-359 kPa (40-48 psi) | 1724-1999 kPa (250-290 psi) | 17°C (62°F) |
Above 20% | 303-359 kPa (44-52 psi) | 1793-2068 kPa (260-300 psi) | 19°C (67°F) | |
47-49°C (116-120°F) | Below 30% | 324-379 kPa (47-55 psi) | 1999-2275 kPa (290-330 psi) | 21°C (70°F) |