Tools Required
J 39400-A Halogen Leak
Detector
Removal Procedure
- Recover the refrigerant from the A/C system. Refer to
Refrigerant Recovery and Recharging
.
- Remove the right wheelhouse panel. Refer to
Wheelhouse Panel Replacement
in Body Front End.
- Remove the evaporator outlet tube retaining
nut (4) from the evaporator.
- Remove the evaporator outlet tube retaining nut (5) from the accumulator.
- Remove the nut (2) from the accumulator bracket.
- Remove the evaporator outlet tube.
- Remove the sealing washers.
Installation Procedure
- Install the new sealing washers. Refer to
Sealing Washer Replacement
.
- Install the evaporator outlet tube to the
accumulator.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the evaporator outlet tube retaining nut to the accumulator.
Tighten
Tighten the nut to 16 N·m (12 lb ft).
- Install the evaporator outlet tube to the evaporator.
Tighten
Tighten the nut to 16 N·m (12 lb ft).
- Install the evaporator outlet tube retaining nut.
Tighten
Tighten the nut to 16 N·m (12 lb ft).
- Install the nut (2) to the accumulator bracket.
Tighten
Tighten the nut to 9 N·m (80 lb in).
- Evacuate and recharge the A/C system. Refer to
Refrigerant Recovery and Recharging
.
- Install the right wheelhouse panel. Refer to
Wheelhouse Panel Replacement
in Body Front End.
- Leak test the fittings of the component using the J 39400-A
.