Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: HVAC Schematics or HVAC Vacuum Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: Air does not flow correctly from the air distribution outlets. | |||
1 | Did you review the HVAC operation and perform the necessary inspections? | Go to Step 2 | |
2 |
Is the blower motor OFF? | Go to Step 3 | Go to Blower Motor Always On |
3 | Place the blower motor switch in each speed position. Does the blower motor operate at all? | Go to Step 4 | Go to Blower Motor Inoperative |
4 | Does the blower motor operate correctly for each speed position? | Go to Step 5 | Go to Blower Motor Malfunction |
5 | Test the Ignition 3 voltage circuit of the vacuum pump assembly for an open, high resistance or short to ground. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 10 | Go to Step 6 |
6 | Test the ground circuit of the vacuum pump assembly for an open or high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 10 | Go to Step 7 |
7 | Disconnect the vacuum hose going to the vacuum pump. Does the vacuum pump turn ON? | Go to Step 8 | |
8 | Inspect for poor connections at the harness connector of the vacuum pump assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 10 | Go to Step 9 |
9 | Replace the vacuum pump assembly. Refer to Vacuum Pump Assembly Replacement . Did you complete the replacement? | Go to Step 10 | -- |
10 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 1 |