Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
A/C Refrigerant Low Pressure Switch Signal Circuit | P0532 | P0532 | P0533 | -- |
Low Reference Circuit | -- | P0533 | -- | -- |
The A/C low pressure switch protects the A/C system. The A/C low pressure switch is a 2-wire normally closed switch. The A/C low pressure switch opens the A/C low pressure switch signal circuit and disables the A/C compressor when line pressure falls below 152 kPa (22 psi). The switch will then close once the pressure reaches 303 kPa (44 psi).
• | Engine is running. |
• | Any of the conditions for setting the DTC are met for 15 seconds. |
• | Battery voltage is between 11-18 volts. |
The ECM detects that the A/C pressure is less than 152 kPa (22 psi).
• | The ECM will not illuminate the malfunction indicator lamp (MIL) |
• | The ECM stores the Failure Records. |
• | The A/C compressor clutch is disabled. |
• | The history DTC will clear after 40 consecutive ignition cycles have occurred without a malfunction. |
• | The DTC will become history if the ECM no longer detects a failure. |
A malfunction within the refrigerant system causing high pressure can cause this DTC to set.
⇒ | If greater than 1 ohm, test the ground circuit for an open/high resistance. |
⇒ | If not the specified value, test the signal circuit for short to ground or an open/high resistance. If the circuit tests normal, replace the ECM. |