Tools Required
J 39400-A Halogen Leak
Detector
Removal Procedure
- Disconnect the A/C refrigerant line.
• | For compression style fittings, use a back up wrench on the fitting
(2) and loosen the fitting nut (1). |
• | For banjo style fittings, remove the bolt retaining the banjo type fitting. |
- Disconnect the A/C line from the A/C component.
- Cap or tape the A/C line and the A/C component to prevent system contamination.
Discard the O-ring seals.
Installation Procedure
- Remove the cap or tape from the A/C line and the A/C component.
- Using a lint-free clean, dry cloth, carefully clean the sealing surfaces
of the A/C refrigerant line and the A/C refrigerant component.
- Lightly coat the new O-ring seal with mineral base 525 viscosity
refrigerant oil.
Important: DO NOT allow any of the mineral base 525 viscosity refrigerant oil
on the new O-ring seal to enter the refrigerant system.
- Carefully slide the new O-ring seal onto the A/C refrigerant line.
- Fully seat the O-ring seal
- Connect the A/C line.
• | For compression style fittings, use a back up wrench on the fitting (2)
and tighten the fitting nut (1) to specification. |
• | For banjo style fittings, install the bolt retaining the banjo type
fitting and tighten to specification. |