Problem
| Action
|
Excessive system leakage is evident.
|
- Inspect for system leakage.
- Repair the system.
|
Excessive leakage is evident in one or more of the following components:
• | The tubing connected to the compressor |
• | The main supply reservoir |
|
- Test the system for leakage at the following components:
• | The safety valve in the air dryer |
- Repair or replace as needed.
|
The internal check valve is faulty.
|
- Remove the check valve from the assembly from the end cover.
- Apply air pressure to the delivery side of the valve.
- Apply a soap solution at the opposite end.
- Inspect for leakage. Permissible air leakage per single connection is 50 sccm (standard cubic centimeters per minute), which is approximately equivalent to s single 1 inch diameter soap bubble in 10 seconds.
- If the leakage is excessive, replace the check valve.
|
The governor is faulty.
|
- Inspect the governor for proper cut-in and cut-out pressures.
- Inspect the governor for excessive leakage in both positions. Refer to
Air Compressor and Governor Valve Diagnosis
.
|
The compressor unloader mechanism is leaking.
|
- Remove the air inlet hose and the fitting from the air compressor inlet cavity.
- Inspect for leakage in the unloader piston while the air compressor is unloaded. Slight leakage is permissible.
|