GM Service Manual Online
For 1990-2009 cars only

Removal Procedure


    Object Number: 830725  Size: SH
  1. Remove the right floor outlet duct retaining screw (3) from the I/P support bracket.
  2. Remove the right floor outlet duct.

Installation Procedure


    Object Number: 830725  Size: SH
  1. Install the right floor outlet duct.
  2. Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.

  3. Install the right floor outlet duct screw (3) to the I/P support bracket.
  4. Tighten
    Tighten the screw to 2 N·m (18 lb in).