Step | Action | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|
Schematic Reference: Headlights/Daytime Running Lights (DRL) Schematics Connector End View Reference: Master Electrical Component List | |||||||||
1 | Did you perform the Diagnostic System Check - Vehicle? | Go to Step 2 | |||||||
2 |
Do the DRLs illuminate? | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 3 | ||||||
3 | Is the brake warning indicator illuminated? | Go to Step 4 | |||||||
4 |
Does the test lamp illuminate? | Go to Step 5 | Go to Step 11 | ||||||
5 |
Do the DRLs illuminate? | Go to Step 6 | Go to Step 12 | ||||||
6 |
Does the test lamp illuminate? | Go to Step 7 | Go to Step 13 | ||||||
7 | Connect a test lamp between the ignition 1 voltage circuit of the DRL relay and the DRL relay control circuit of the DRL relay. Does the test lamp illuminate? | Go to Step 9 | Go to Step 8 | ||||||
8 | Test the DRL relay control circuit for the following:
Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 16 | Go to Step 10 | ||||||
9 | Inspect for poor connections at the DRL relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 16 | Go to Step 14 | ||||||
10 | Inspect for poor connections at the harness connector of the DRL control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 16 | Go to Step 15 | ||||||
11 | Repair an open, high resistance or short to ground in the DRL diode supply voltage circuit. Refer to Circuit Testing and Wiring Repairs . Did you complete the repair? | Go to Step 16 | -- | ||||||
12 | Repair an open, high resistance or short to ground in the headlamp low beam supply voltage circuit. Refer to Circuit Testing and Wiring Repairs . Did you complete the repair? | Go to Step 16 | -- | ||||||
13 | Repair an open, high resistance or short to ground on the ignition 1 voltage circuit of the DRL relay. Refer to Circuit Testing and Wiring Repairs . Did you complete the repair? | Go to Step 16 | -- | ||||||
14 | Replace the DRL relay. Refer to Relay Replacement . Did you complete the replacement? | Go to Step 16 | -- | ||||||
15 | Replace the DRL control module. Refer to Control Module References for replacement, setup, and programming. Did you complete the replacement? | Go to Step 16 | -- | ||||||
16 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |