- Rotate the engine so that the timing marks on the front cover and the crankshaft pulley are aligned. Number 1 cylinder should be at top dead center (TDC).
- Before adjusting the valve clearance, loosen the adjustment screw both on the rocker arm and the valve bridge.
Important: Adjust the intake valves on cylinders 1, 2, and 4.
Adjust the exhaust valves on cylinders 1, 3, and 5.
Adjust all the valve clearances to 0.4 mm (0.016 in).
- Insert a feeler gage between the rocker arm and the cap of the valve bridge, and adjust by turning the adjusting screw on the rocker arm, until there is a slight drag on the feeler gage.
- Tighten the lock nut securely.
- With a feeler gage inserted, screw in the adjusting screw on the bridge gradually, until it touches the end of the valve stem, then ensure that the movement of the feeler gage becomes hard.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- In this condition, the opposite end of the bridge is raised. Readjust by loosening the adjusting screw on the bridge, until there is a slight drag on the feeler gage, then tighten the lock nut securely.
Tighten
Tighten the adjusting lock nut to 22 N·m (16 lb ft).
- Rotate the engine one full turn so that the timing marks on the crankshaft balancer and the front cover are in alignment again.
Important: Adjust the intake valves on cylinders 3, 5, and 6.
Adjust the exhaust valves on cylinders 2, 4, and 6.
Adjust all the valve clearances to 0.4 mm (0.016 in).
- Insert a feeler gage between the rocker arm and the cap of the valve bridge, then adjust by turning the adjusting screw on the rocker arm, until there is a slight drag on the feeler gage.
- Tighten the lock nut securely.
- With a feeler gage inserted, screw in the adjusting screw on the bridge gradually, until it touches the end of the valve stem, then make sure that the movement of the feeler gage becomes hard.
- In this condition, the opposite end of the bridge is raised. Readjust by loosening the adjusting screw on the bridge, until there is a slight drag on the feeler gage, then tighten the lock nut securely.
Tighten
Tighten the adjusting lock nut to 22 N·m (16 lb ft).
- Recheck all the valve clearances and readjust if necessary.