- Install the recirculation door (1) to the evaporator and blower module assembly (6).
- Install the recirculation door actuator (7) and the linkage.
- Install the evaporator and blower module assembly cover (3).
Notice: Refer to Fastener Notice in the Preface section.
- Install the screws.
Tighten
Tighten the screws to 1.9 N·m (17 lb in).
- Install new sealing washers to the evaporator inlet and outlet tubes. Refer to
O-Ring Replacement .
- Install the evaporator inlet tube (1) to the evaporator.
- Install the evaporator inlet tube retaining nut (3).
Tighten
Tighten the nut to 16 N·m (12 lb ft).
- Install the evaporator outlet tube to the evaporator.
- Install the evaporator outlet tube retaining nut (4).
Tighten
Tighten the nut to 16 N·m (12 lb ft).
- Install the multi-use module bracket. Refer to the appropriate procedure:
• | Caterpillar® 3126 Unit Repair Manual |
- Install the accumulator (5) to the bracket.
- Install the nuts (3) to the accumulator retaining bracket.
Tighten
Tighten the nuts to 9 N·m (80 lb in).
- Install new O-ring seals. Refer to
O-Ring Replacement .
- Install the evaporator outlet hose.
- Install the evaporator outlet hose retaining nut (5) to the accumulator.
Tighten
Tighten the nut to 18 N·m (13 lb ft).
- Install the compressor suction hose to the accumulator.
- Install the compressor inlet hose retaining nut (2) to the accumulator.
Tighten
Tighten the nut to 18 N·m (13 lb ft).
- Connect the electrical connectors to the low pressure sensor.
- Connect the electrical connector to the blower motor assembly.
- Connect the electrical connector to the blower motor resistor assembly.
- Install the air cleaner. Refer to the appropriate procedure:
• | Caterpillar® 3126 Unit Repair Manual for the 7.2L (Caterpillar) engine |
- Install the right wheelhouse panel. Refer to
Wheelhouse Panel Replacement .
- Evacuate and recharge the A/C system. Refer to
Refrigerant Recovery and Recharging .