Removal Procedure
- Remove the I/P cluster trim plate. Refer to
Instrument Panel Cluster Trim Plate Bezel Replacement
.
- Remove the retaining screw (3) from the HVAC control assembly (4).
- Pivot the HVAC control assembly to disengage the locking tab on the right side.
- Disconnect the electrical connectors (1).
- Disconnect the vacuum connector (2).
- Remove the HVAC control assembly.
Installation Procedure
- Connect the vacuum connector (2).
- Connect the electrical connectors (1).
- Install the HVAC control assembly.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the retaining screw (3) to the HVAC control assembly (4).
Tighten
Tighten the screw to 2 N·m (18 lb in).
- Install the I/P cluster trim plate. Refer to
Instrument Panel Cluster Trim Plate Bezel Replacement
.