GM Service Manual Online
For 1990-2009 cars only

Battery Negative Cable Replacement LG5 Starter MotorGround Cable

Removal Procedure


    Object Number: 215031  Size: SH
  1. Remove the negative cable from the starter.
  2. Remove the negative cable from the engine block.

Installation Procedure

  1. Clean the grounding area. Coat the grounding area with a copper-impregnated ground sealer.

  2. Object Number: 215031  Size: SH
  3. Connect the negative cable to the engine block.
  4. Notice: Refer to Fastener Notice in the Preface section.

  5. Install the negative cable to the starter.
  6. Tighten

        • Tighten the negative cable to the starter to 30 N·m (22 lb ft).
        • Tighten the negative cable to the engine block to 28 N·m (21 lb ft).

Battery Negative Cable Replacement LG4 Ground Cable

Removal Procedure

    Caution: Unless directed otherwise, the ignition and start switch must be in the OFF or LOCK position, and all electrical loads must be OFF before servicing any electrical component. Disconnect the negative battery cable to prevent an electrical spark should a tool or equipment come in contact with an exposed electrical terminal. Failure to follow these precautions may result in personal injury and/or damage to the vehicle or its components.


    Object Number: 206085  Size: SH
  1. Remove the nut , bolt , washer, and the negative cable from the frame.
  2. Remove the bolt, washer, and the negative cable from the engine.
  3. Remove the negative cable .

Installation Procedure


    Object Number: 206085  Size: SH
  1. Install the negative cable to the engine with bolt and washer.
  2. Clean the grounding area of the frame. Coat the surrounding area with a copper-impregnated ground sealer.
  3. Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.

  4. Install the negative cable nut, washer, and bolt to the frame.
  5. Tighten

        • Tighten the negative cable to the frame bolt to 28 N·m (21 lb ft).
        • Tighten the negative cable to the engine bolt to 30 N·m (22 lb ft).

Battery Negative Cable Replacement LLY/LMM w/o ANC/B3D


Object Number: 1869777  Size: MF

Callout

Component Name

Preliminary Procedure

Disconnect the negative battery cable. Refer to Battery Negative Cable Disconnection and Connection .

1

Tie Strap (Qty: 3)

Procedure

Cut the tie straps.

2

Battery Positive and Negative Cable Clip Nut (Qty: 4)

Notice: Refer to Fastener Notice in the Preface section.

Tighten
30 N·m (22 lb ft)

3

Battery Positive and Negative Cable Clip (Qty: 4)

4

Battery Positive Cable Junction Block

Procedure

Open the junction block cover.

5

Battery Positive Cable Extension Cable Junction Block Lead Nut

Tighten
25 N·m (18 lb ft)

6

Battery Positive and Negative Cable Clamp

7

Battery Cable Retainer Bolt

Tighten
25 N·m (18 lb ft)

8

Battery Cable Retainer

9

Battery Positive Cable Nut

Tighten
9 N·m (80 lb in)

10

Battery Negative Cable Ground Bolt

Tighten
50 N·m (37 lb ft)

11

Battery Negative Cable Ground Washer

12

Battery Cable Assembly (dual batteries shown, triple batteries similar)

Procedure

Open the battery cable conduit.

13

Battery Negative Cable

Battery Negative Cable Replacement LLY/LMM w/ANC/B3D


Object Number: 1869836  Size: LF

Callout

Component Name

Preliminary Procedure

Disconnect the negative battery cable. Refer to Battery Negative Cable Disconnection and Connection .

1

Tie Strap (Qty: 2)

Procedure

Cut the tie straps.

2

Battery Negative Cable Ground Bolt

Notice: Refer to Fastener Notice in the Preface section.

Tighten
50 N·m (37 lb ft)

3

Battery Negative Cable Ground Washer

4

Battery Cable Conduit

Procedure

Open the battery cable conduit.

5

Battery Negative Cable