Note: When replacing battery cables, use a replacement cable that is the same type, diameter, and length. Additional feed wires may be attached to the positive cables. Additional ground leads may be attached to the negative cables. Always route a replacement battery cable the same as the original cable routing.
Warning: Refer to Battery Disconnect Warning in the Preface section.
Caution: Refer to Fastener Caution in the Preface section.
Tighten
Tighten the positive cable to the Maxi-Fuse® block bolt to 11 N·m (97 lb in).
Tighten
• | Tighten the positive cable starter nut to 10 N·m (89 lb in). |
• | Tighten the positive cable starter nut to 30 N·m (22 lb ft). |
Tighten
• | Tighten the side post terminal bolt to 15 N·m (11 lb ft). |
• | Tighten the top post terminal nut to 17 N·m (13 lb ft). |
Callout | Component Name |
---|---|
Preliminary ProcedureDisconnect the negative battery cable. Refer to Battery Negative Cable Disconnection and Connection. | |
1 | Tie Strap (Qty: 3) ProcedureCut the tie straps. |
2 | Battery Positive Cable Clip Bolt Cap (Qty: 2) |
3 | Battery Cable Terminal Nut (Qty: 2) Caution: Refer to Fastener Caution in the Preface section. Tighten |
4 | Battery Positive Cable Clip |
5 | Battery Positive Cable Clip Nut (Qty: 3) Tighten |
6 | Battery Positive Cable Clamp |
7 | Battery Cable Retainer Bolt Tighten |
8 | Engine Wiring Harness Clamp |
9 | Battery Positive Cable Nut Tighten |
10 | Battery Positive Cable Junction Block ProcedureOpen the junction block cover. |
11 | Battery Positive Cable Extension Cable Junction Block Lead Nut Tighten |
12 | Battery Positive Cable Assembly ProcedureOpen the battery cable conduit. |
13 | Battery Positive Cable ProcedureReplace the appropriate positive cable. |
Callout | Component Name |
---|---|
Preliminary ProcedureDisconnect the negative battery cable. Refer to Battery Negative Cable Disconnection and Connection. | |
1 | Tie Strap (Qty: 3) ProcedureCut the tie straps. |
2 | Battery Positive and Negative Cable Clip Nut (Qty: 4) Caution: Refer to Fastener Caution in the Preface section. Tighten |
3 | Battery Positive and Negative Cable Clip (Qty: 4) |
4 | Battery Positive Cable Junction Block ProcedureOpen the junction block cover. |
5 | Battery Positive Cable Extension Cable Junction Block Lead Nut Tighten |
6 | Battery Positive and Negative Cable Clamp |
7 | Battery Cable Retainer Bolt Tighten |
8 | Battery Cable Retainer |
9 | Battery Positive Cable Nut Tighten |
10 | Battery Negative Cable Ground Bolt Tighten |
11 | Battery Negative Cable Ground Washer |
12 | Battery Cable Assembly (dual batteries shown, triple batteries similar) ProcedureOpen the battery cable conduit. |
13 | Battery Positive Cable (Qty: 2) ProcedureReplace the appropriate positive cable. |