• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | High Resistance | Open | Short to Voltage | Signal Performance |
---|---|---|---|---|---|
FRP Signal | P0192 | P0088, P0191 | P0193 | P0193 | -- |
FRP Low Reference | -- | P0191 | P0193 | ¹ | -- |
FRP 5-Volt Reference | P0117, P0462, P0522, P0652 | P0087, P0191 | P0193 | P0118, P0653 | -- |
Fuel Pressure Regulator Solenoid Supply Voltage | P0088, P0090 | P0088 | P0090 | P0087, P0191, P2510 | -- |
¹ Opens circuit fuse or opens circuit. |
Circuit | Short to Ground | High Resistance | Open | Short to Voltage |
---|---|---|---|---|
Operating Conditions: The Ignition ON, with the Engine OFF Parameter Normal Range: 0.352-0.650 volt | ||||
5-Volt Reference | 0 MPa (0 psi) | Varies¹ | 200 MPa (29,000 psi) | 0 MPa (0.0 psi) |
FRP Sensor Signal | 0 MPa (0 psi) | Varies¹ | 200 MPa (29,000 psi) | 200 MPa (29,000 psi) |
FRP Sensor Low Reference | -- | Varies¹ | 200 MPa (29,000 psi) | Note² |
Fuel Pressure Regulator Solenoid Supply Voltage | 0.2 MPa (34.8 psi)¹ | 71 MPa (10,300 psi)¹ | 0.2 MPa (34.8 psi)¹ | 0.2 MPa (34.8 psi)¹ |
¹ Fuel pressure erratic ² Opens circuit fuse or opens circuit |
The fuel rail pressure (FRP) sensor has a 5-volt reference circuit, a signal circuit, and a low reference circuit. The engine control module (ECM) monitors the voltage on the FRP sensor circuits. When the fuel pressure is high, the signal voltage is high. When the fuel pressure is low, the signal voltage is low. The fuel pressure regulator has a solenoid supply voltage circuit and a solenoid control circuit. The ECM controls the fuel pressure regulator , which regulates high pressure fuel that goes to the fuel injector rails and the injectors.
• | DTCs P0016, P062F, P0116, P0117, P0118, P0192, P0193, P0652 or P0653 are not set. |
• | The ignition is ON, with the engine OFF for 30 seconds. |
• | The coolant temperature has dropped more than 5°C (9°F) since Last Key Cycle. |
• | The FRP sensor voltage is between 352-650 volts. |
OR |
• | The ignition has been off less than 70 seconds. |
• | The fuel temperature is more than 60°C (140°F). |
• | The FRP sensor voltage is between 352-650 volts. |
• | This diagnostic runs continuously within the above conditions. |
• | The FRP sensor is below 0.352 volt or above 0.650 volt when the ignition is ON and the engine is OFF. |
OR |
• | The FRP sensor is below 0.352 volt or above 0.650 volt within 70 seconds of the ignition being turned OFF. |
DTC P0191 is a Type A DTC.
DTC P0191 is a Type A DTC.
Powertrain Diagnostic Trouble Code (DTC) Type Definitions
Important:
• You must perform the Circuit/System Verification before proceeding with Circuit/System Testing. • If you cannot duplicate the condition, operate the vehicle within the Conditions for Running the DTC. You may also operate the vehicle within the conditions that you observed from the Freeze Frame/Failure Records.
⇒ | If any of the DTCs are set, refer to Diagnostic Trouble Code (DTC) List - Vehicle . |
Important: Fuel pressure control will be disable if DTC P0087, P0088, P0192, or P0193 are set. Codes must be cleared to enable the device control.
⇒ | If all circuits test normal, replace the FRP sensor. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for ECM replacement, programing and setup |