Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Air Suspension Schematics Connector End View Reference: Air Suspension Connector End Views | |||
1 | Did you review the system and circuit description and perform the necessary electrical and mechanical inspections? | Go to Step 2 | |
2 | Verify the fault is present. Does the system operate normally? | Go to Step 3 | |
3 |
Does the test lamp illuminate? | Go to Step 4 | Go to Step 6 |
4 |
Does the test lamp illuminate? | Go to Step 5 | Go to Step 7 |
5 | Test the air suspension dump solenoid control circuit for a short to voltage. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 10 | -- |
6 | Inspect for poor connections at the air suspension dump solenoid. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 10 | Go to Step 8 |
7 | Inspect for poor connections at the air suspension dump switch. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 10 | Go to Step 9 |
8 | Replace the air suspension dump solenoid. Refer to Air Suspension Relief Valve Replacement . Did you complete the replacement? | Go to Step 10 | -- |
9 | Replace the air suspension dump switch. Did you complete the replacement? | Go to Step 10 | -- |
10 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |