Removal Procedure
Note: The blower motor relay is an integral part of the blower motor resistor and cannot be serviced separately from the resistor.
- Disconnect the electrical connectors from the blower motor resistor assembly and the blower motor.
- Remove the blower motor resistor assembly retaining screws.
- Remove the blower motor resistor assembly (2) from the evaporator and blower module assembly (3).
Installation Procedure
- Install the blower motor resistor assembly (2) to the evaporator and blower module assembly (3).
Caution: Refer to Fastener Caution in the Preface section.
- Install the blower motor resistor assembly retaining screws.
Tighten
Tighten the screws to 2 N·m (18 lb in).
- Connect the electrical connectors to the blower motor resistor assembly and the blower motor.