Removal Procedure
- Drain all of the air from the air supply system.
- Mark both of the air lines to the leveling valve.
- Remove the valve locknut (2) that fastens the control valve link (5) to the control valve (1).
- Remove the following components:
• | The leveling valve locknuts (1) |
- Remove the height leveling valve (2).
- Remove the brass air fittings from the height leveling valve.
Installation Procedure
- Install the brass air fitting on the leveling valve.
- Connect the leveling valve in position on the frame.
Caution: Refer to Fastener Caution in the Preface section.
- Install the following components:
• | The leveling valve locknuts (1) |
Tighten
Tighten the leveling valve mounting locknuts to 95 N·m (70 lb ft) for models without RPO-GPG.
- Connect the leveling valve air lines to the correct ports on the leveling valve.
- Connect the control valve link (5) on the control valve (1).
- Install the locknut that connects the control valve link to the control valve.
Tighten
Tighten the locknut to 23 N·m (17 lb ft).
- Apply air pressure. Inspect the valve for leaks.