Removal Procedure
- Remove the transmission fluid level indicator.
- If required, remove the transmission shift cable from the tube straps.
- Remove the bolts, and the filler from the transmission.
- If servicing the indicator tubes from the left side, remove the bolts, the nuts and the straps.
Installation Procedure
- Install the new indicator tube seal to the transmission.
- Install the filler tube to the transmission.
Caution: Refer to Fastener Caution in the Preface section.
- Install the indicator tube bolts.
Tighten
Tighten the indicator tube bracket bolts to 25 N·m (18 lb ft).
- Install the transmission fluid level indicator.
- Install the transmission shift cable to the filler tube straps as required.
- Inspect and fill the transmission to the proper level with DEXRON III fluid or Allison TransSynd™ Full Synthetic Fluid. Refer to
Fluid Capacity Specifications.