Special Tools
J 39400-A Halogen Leak Detector
Removal Procedure
- Recover the refrigerant from the A/C system. Refer to
Refrigerant Recovery and Recharging.
- Remove the evaporator outlet hose retaining nut (5) from the accumulator.
- Remove the compressor inlet hose retaining nut (2).
- Disconnect the low pressure sensor electrical connector.
- Remove the retaining nuts (3) from the accumulator retaining bracket.
- Remove the accumulator (5) from the bracket.
- Remove the sealing washers.
Installation Procedure
- Add oil to the accumulator. Refer to
Refrigerant System Capacities.
- Install the accumulator (5) to the bracket.
Caution: Refer to Fastener Caution in the Preface section.
- Install the nuts (3) to the accumulator retaining bracket.
Tighten
Tighten the nuts to 9 N·m (80 lb in).
- Connect the low pressure sensor electrical connector.
- Install new sealing washers. Refer to
O-Ring Replacement.
- Install the evaporator outlet hose.
- Install the evaporator outlet hose retaining nut (5) to the accumulator.
Tighten
Tighten the nut to 16 N·m (12 lb ft).
- Install the compressor inlet hose.
- Install the compressor inlet hose retaining nut (2) to the accumulator.
Tighten
Tighten the nut to 16 N·m (12 lb ft).
- Evacuate and recharge the A/C system. Refer to
Refrigerant Recovery and Recharging.
- Leak test the fittings of the component using the
J 39400-A .