Table 1: | Normal Device Power Moding |
Table 2: | Code Setting Criteria -- Fault for Device Power Moding |
Class 2 communications will not start until the vehicle systems "on" power mode has been identified. Three discrete wires from the ignition switch contacts are monitored by the instrument panel cluster (IPC) in order to determine the present power mode -- ignition switch position. The IPC communicates the system power mode to all class 2 modules on the class 2 serial data line.
The IPC must be powered.
One of the three monitored ignition switch circuits has malfunctioned.
The IPC implements default actions for each ignition switch position when faults are detected.
The power moding malfunction must be corrected and then the code can be cleared by using the scan tool. The code also clears after 100 ignition cycles.
Key Position | ACC | IGN 1 | IGN 0 | Engine Running | Power Mode |
---|---|---|---|---|---|
OFF/AWAKE | Inactive | Inactive | Inactive | No | OFF/AWAKE |
UNLOCK | Inactive | Inactive | Active | No | UNLOCK |
CRANK | Inactive | Active | Active | No | CRANK |
ACC | Active | Inactive | Inactive | No | ACC |
UNLOCK | Active | Inactive | Active | No | UNLOCK |
RUN | Active | Active | Active | No | RUN |
OFF/AWAKE | Inactive | Inactive | Inactive | Yes | OFF/AWAKE |
UNLOCK | Inactive | Inactive | Active | Yes | UNLOCK |
RUN | Active | Active | Active | Yes | RUN |
ACC | IGN 1 | IGN 0 | Engine Running | Power Mode (Default) |
---|---|---|---|---|
Inactive | Active | Inactive | No | OFF/AWAKE |
Active | Active | Inactive | No | RUN |
Inactive | Active | Inactive | Yes | RUN |
Inactive | Active | Active | Yes | RUN -- Fault is set only if this condition exists for more than 1 minute |
Active | Inactive | Inactive | Yes | RUN |
Active | Inactive | Active | Yes | RUN |
Active | Active | Inactive | Yes | RUN |
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Instrument Cluster Schematics Connector End View Reference: Instrument Panel, Gages, and Console Connector End Views | |||
1 | Did you perform the Instrument Cluster Diagnostic System Check? | Go to Step 2 | |
2 |
Does the scan tool display Active for both parameters? | Go to Step 3 | Go to Step 4 |
3 |
Does the scan tool display Inactive? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 5 |
4 | Test the ignition voltage circuit for an open, for a high resistance or for a short to ground. Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 8 | Go to Step 6 |
5 | Test the ignition 1 voltage circuit for a short to voltage. Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 8 | Go to Step 6 |
6 | Inspect for poor connections at the harness connector of the instrument panel cluster (IPC). Refer to Testing for Intermittent Conditions and Poor Connections and to Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 8 | Go to Step 7 |
7 |
Important: Program the replacement IPC Replace the IPC. Refer to Instrument Cluster Replacement .Did you complete the replacement? | Go to Step 8 | -- |
8 |
Does the DTC reset? | Go to Step 2 | System OK |