Modules connected to the class 2 serial data circuit monitor for serial data communications during normal vehicle operation. Operating information and commands are exchanged among the modules. Connecting a scan tool to the DLC allows communication with the modules for diagnostic purposes. Diagnostic trouble codes (DTCs) may be set due to this symptom and during this diagnostic procedure. Complete the diagnostic procedure in order to ensure all the DTCs are diagnosed and cleared from memory.
• | The VCM (Gas) and PCM (Diesel) detects that the ignition is ON and sends the appropriate power mode message to the other modules. Therefore, the VCM (Gas) and PCM (Diesel) must be connected to the DLC for any other module to communicate with the scan tool. |
• | When the class 2 serial data circuit is shorted to ground, U1300 or U1305 will be set. Refer to DTC U1300 Class 2 Data Link Low or DTC U1300 Class 2 Data Link Low . |
• | When the class 2 serial data circuit is shorted to B+ U1301 or U1305 will be set. Refer to DTC U1301 Class 2 Data Link High or DTC U1301 Class 2 Data Link High . |
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 |
Is the voltage reading greater than the specified value? | 7 volts | Go to Step 2 | Go to Step 9 |
2 |
Is the voltage reading greater than the specified value? | 7 volts | Go to Step 5 | Go to Step 3 |
3 |
Is the voltage reading greater than the specified value | 7 volts | Go to Step 4 | Go to Step 17 |
4 |
Is the voltage reading greater than the specified value? | 7 volts | Go to Step 7 | Go to Step 17 |
5 |
Is the voltage reading greater than the specified value? | 7 volts | Go to Step 6 | Go to Step 17 |
6 |
Is the voltage reading greater than the specified value | 7 volts | Go to Step 8 | Go to Step 17 |
7 | Locate and repair the short to voltage in CKT 1807 (PPL) between C100 and the EBCM, VCM/PCM. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 18 | -- |
8 |
Is the repair complete? | -- | Go to Step 18 | -- |
9 |
Is continuity present? | -- | Go to Step 10 | Go to Step 18 |
10 |
Is continuity present? | -- | Go to Step 13 | Go to Step 11 |
11 |
Is continuity present? | -- | Go to Step 12 | Go to Step 17 |
12 |
Is continuity present? | -- | Go to Step 15 | Go to Step 17 |
13 |
Is the continuity present? | -- | Go to Step 14 | Go to Step 17 |
14 |
Is continuity present? | -- | Go to Step 16 | Go to Step 17 |
15 | Locate and repair the short to ground in CKT 1807 (PPL) between C100 and the EBCM, VCM/PCM. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 18 | -- |
16 |
Is the repair complete? | -- | Go to Step 18 | -- |
17 | Replace the control module that you disconnected last. Is the repair complete? | -- | Go to Step 18 | -- |
18 |
Does the DTC reset? | -- | Go to Step 1 | OK |