Removal Procedure
- Remove the IP cluster bezel. Refer to
Instrument Panel Cluster Trim Plate Bezel Replacement
in Instrument Panel, Gauges and
Console.
- Remove the HVAC control
assembly by releasing the retainers.
- Disconnect the electrical connector from the HVAC control assembly.
- Remove the cables from the control assembly by releasing the retainers.
- Remove the blower switch rotary knob from the shaft of the blower
switch.
- Remove the blower switch from the HVAC control assembly.
Installation Procedure
- Install the blower switch.
- Install the blower switch rotary knob
- Install the cables to the HVAC control assembly.
- Connect the electrical connector to the HVAC control assembly.
- Install the HVAC control
assembly into the instrument panel.
- Install the instrument panel trim plate. Refer to
Instrument Panel Cluster Trim Plate Bezel Replacement
in Instrument Panel, Gauges and
Console.