Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Has the Heater Blower Controls System Check been performed? | -- | Go to Step 2 | |
2 |
Does the Auxiliary Blower Motor stop running? | -- | Go to Step 3 | Go to Step 4 |
3 | Replace the Auxiliary Blower Motor Relay that you last removed. Refer to Blower Motor Relay Replacement . Is the repair complete? | -- | -- | |
4 | Connect a DMM (volts) between cavity 4 of the high relay socket and ground. Is voltage greater than the value given? | 1 volt | Go to Step 5 | |
5 | Locate and repair the short to voltage in CKT 1172 (YEL) between the Auxiliary Blower Motor, the Auxiliary Blower Motor Relay, High and the Auxiliary Blower Resistor. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- |