Removal Procedure
- Disconnect the electrical connector to the mode actuator that
is located on the left side of the air distribution case.
- Remove the screws.
- Remove the adjuster links from the control lever.
- Remove the mode actuator.
- Adjust the mode actuator by completing the following steps:
5.1. | Connect the electrical connector to the actuator. |
5.2. | Turn the ignition switch to the RUN position. |
Allow the self-positioning of the actuator.
5.3. | Turn the ignition switch to the OFF position. |
5.4. | Remove the actuator from the electrical connection. |
Installation Procedure
- Install the mode actuator.
- Install the screws.
- Install the adjuster links to the control lever.
- Connect the electrical connector.